VUE FWD L4-2.4L Hybrid (2007)
13. Remove the 36-volt negative battery cable lead from the generator battery.
14. Remove the 36-volt positive battery cable lead nut (6).
15. Remove the 36-volt positive battery cable lead (5).
16. Secure the cables out of the way, ensuring that the cables CANNOT be re-installed without your knowledge.
Connect Procedure
1. Install the 36-volt positive battery cable lead (6) to the generator battery.
Notice: Refer to Fastener Notice.
2. Install the 36-volt positive battery cable lead nut (6).
Tighten the nut to 15 N.m (11 lb ft).