VUE FWD L4-2.4L Hybrid (2007)
Hybrid Power Control Module: All Technical Service Bulletins
Hybrid Systems - Supersession of Battery Disconnect Unit
INFORMATION
Bulletin No.: 10-06-130-001
Date: January 27, 2010
Subject: Supersession of Battery Disconnect Unit (BDU) [Module Asm - Bat Engy Cont]
Models:
2007 Saturn VUE Green Line Hybrid
The original BDU assembly is being superseded to the same part numbers used in the 2007-2009 AURA vehicles. This replacement BDU has a shorter
wiring harness pig tail, a different fan wiring connector and different programming.
To install the replacement BDU, it will be necessary to add a "jumper" to account for the wiring length change, replace the cooling fan assembly with
one that has the new connector and program the BDU using SPS after installation into the vehicle. Refer to the Parts Information below for the
replacement BDU, harness assembly-drive motor battery disconnect module and cooling fan assembly.
Refer to Battery Energy Control Module Replacement in SI for installation procedures.
Important
The replacement BDU must be programmed with SPS after installation or DTC(s) will be set.
Refer to Battery Energy Control Module Replacement in SI for installation procedures.
Parts Information