saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1785 > < Diagram Information and Instructions|Page 1783
Page 76
background image

of the DuraSeal splice sleeves and the crimp tool nests.

5.  Use the Splice Crimp Tool from the J 44020 in order to position the DuraSeal splice sleeve in the proper color nest of the Splice Crimp Tool.

The crimp tool has 3 nests, 1 is for the salmon and green splice sleeves, 2 is for the blue splice sleeves, and 3 is for the yellow splice sleeves.

6.  Place the DuraSeal splice sleeve in the nest. Ensure that the crimp falls midway between the end of the barrel and the stop. The sleeve has a stop

(3) in the middle of the barrel (2) in order to prevent the wire (1) from going further. Close the hand crimper handles slightly in order to firmly
hold the DuraSeal splice sleeve in the proper nest.

7.  Insert the wire into the splice sleeve barrel until the wire hits the barrel stop.
8.  Tightly close the handles of the crimp tool until the crimper handles open when released.

The crimper handles will not open until you apply the proper amount of pressure to the DuraSeal splice sleeve. Repeat steps 4 and 5 for the
opposite end of the splice.

9.  Using the heat gun, apply heat to the crimped area of the barrel.

10.  Start in the middle and gradually move the heat barrel to the open ends of the tubing:

*  The tubing will shrink completely as the heat is moved along the insulation.
*  A small amount of sealant will come out of the end of the tubing when sufficient shrinkage is achieved.

Heated Oxygen Sensor Wiring Repairs

Heated Oxygen Sensor Wiring Repairs

Tools Required

Diagram Information and Instructions|Page 1785 > < Diagram Information and Instructions|Page 1783