saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Emissions - MIL ON/DTC P0442 Is Set|Page 3558 > < Engine - Squealing Type Noise on Start-up or Vibration
Page 1
background image

Evaporative Canister Filter: All Technical Service Bulletins
Emissions - MIL ON/DTC P0442 Is Set

TECHNICAL

Bulletin No.: 08-06-04-020B

Date: January 26, 2009

Subject: 
Malfunction Indicator Light (MIL) - Check Engine Light On, DTC P0442 Set (Inspect for Leak Between EVAP Canister and Filter Assembly)

Models:
2008 Saturn VUE

Built Prior to January 14, 2008

Supercede:

This bulletin is being revised to update the parts information. Please discard Corporate Bulletin Number 08-06-04-020A (Section 06 - Engine/Propulsion
System).

Condition

Some customers may comment that the check engine light is on. Upon investigation, the technician may find DTC P0442 (EVAP Small Leak Detected)
set as current or in history.

Cause

This condition may be caused by an EVAP system leak due to the O-ring seal between the filter and canister being rolled, causing the canister to be
distorted.

Correction

Technicians are to perform a leak test and if a leak is found between the canister and filter, replace the canister and filter. To correctly repair this
condition, BOTH the canister and filter must be replaced.

1.

Perform the leak test using the Evaporative Emission System Tester (EEST). Refer to the Evaporative Emission System Diagnosis in SI for
instructions on the tester.

2.

Lower the canister and inspect the vent area between the canister and filter (see image above).

3.

If the smoke is coming from between the filter and canister, the O-ring between the canister and filter is likely rolled.

4.

Replace the filter and canister as an assembly.

Parts Information