saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Fuel Supply Line > < Fuel Return Line|Service and Repair|Page 9252
Page 10
background image

16. Connect the chassis fuel feed line quick connect fitting (2) to the fuel rail. Refer to Metal Collar Quick Connect Fitting Service  (See: Fuel Line

Coupler/Service and Repair/Metal Collar Quick Connect Fitting Service) .

17. Connect the chassis EVAP line quick connect fitting (3) to the EVAP canister purge solenoid valve. Refer to Plastic Collar Quick Connect Fitting

Service  (See: Fuel Line Coupler/Service and Repair/Plastic Collar Quick Connect Fitting Service) .

18. Install the retaining clip (1) to the MAP sensor bracket.
19. Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement  (See: Air Cleaner Housing/Air Cleaner Fresh Air

Duct/Hose/Service and Repair/Air Cleaner Outlet Duct Replacement) .

20. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (Without LAT-2.4L)  (See: Starting and

Charging/Battery/Battery Cable/Service and Repair) .

21. Use the following procedure in order to inspect for leaks:

1. Turn the ignition ON, with the engine OFF, for 2 seconds.
2. Turn the ignition OFF for 10 seconds.
3. Turn the ignition ON, with the engine OFF.
4. Inspect for fuel leaks.

22. Install the intake manifold cover. Refer to Intake Manifold Cover Replacement  (See: Engine, Cooling and Exhaust/Engine/Intake

Manifold/Service and Repair) .

Fuel Supply Line > < Fuel Return Line|Service and Repair|Page 9252