saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Air Inlet Valve Actuator Replacement|Page 9808 > < Air Inlet Valve Actuator Replacement|Page 9806
Page 6
background image

1. Remove the instrument panel compartment. Refer to Instrument Panel Compartment Replacement   (See: Body and Frame/Interior Moulding /

Trim/Glove Compartment/Service and Repair).

2. Disconnect the electrical connector from the air temperature actuator.
3. Remove the air temperature actuator screws from the HVAC module.
4. Remove the air temperature actuator from the HVAC module.

Installation Procedure

1. Align the air temperature actuator with the door shaft and rotate into position.

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution).

2. Install the air temperature actuator screws to the HVAC module.

Tighten the screws to 1.5 Nm (13 lb in).

3. Connect the electrical connector to the air temperature actuator.

Air Inlet Valve Actuator Replacement|Page 9808 > < Air Inlet Valve Actuator Replacement|Page 9806