saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Drive Motor Generator Power Inverter Module Removal and Installation|Page 2729 > < Drive Motor Generator Power Inverter Module Removal and Installation|Page 2727
Page 5
background image

4. Rotate the drive motor generator control module assembly onto the APM.
5. Clamp the GE-48494 - adapter kit components (2, 3) to a coolant pipe.
6. Plug the remaining coolant pipe with the GE-48494 - adapter kit plug and clamp (1).
7. Apply 20 psi (138 kPa) pressure with J 24460-01 - pressure tester  (4).
8. Monitor the pressure tester gauge for 5 minutes and ensure that pressure remains at the specified value.

*

If the specified pressure cannot be maintained, disassemble the drive motor generator control module assembly and replace the coolant seals.

*

If pressure remains at the specified value, proceed to the next step.

9. Remove all GE-48494 - adapter kit components.

10. Remove the PIM cover bolts (1).
11. Remove the PIM cover (2).

Drive Motor Generator Power Inverter Module Removal and Installation|Page 2729 > < Drive Motor Generator Power Inverter Module Removal and Installation|Page 2727