30. Remove the underhood fuse block support fastener (1) and pull the support away from the control module.
31. Remove the engine coolant recovery reservoir support fastener (2).

Note:  A service replacement APM does not have the engine coolant recovery reservoir support stud installed. Remove and save the stud for
installation onto the replacement APM.

32. Remove the engine coolant recovery reservoir support stud (3) from the control module.

33. Remove the generator control module coolant inlet hose (2) and hose clamp (1) from the control module radiator.