9. Install the APM ground strap (2) and APM ground strap nut (1) onto the left front inner fender stud and tighten to 9 Nm (80 lb in).

10. Install the hybrid cooling surge tank (2) onto the control module and body support stud (4). Install the control module fasteners (1, 3) and tighten

to 7.5 Nm (66 lb in).