12. Press Start to continue.

Note:  Approximately 2.5-3.0 L (2.6-3.2 qt) of brake fluid will be used throughout this procedure. Ensure there is an adequate supply of brake
fluid in the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder.

13. Inspect the fluid level in the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder. Clean the outside of the J-29532 -

Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder and add GM approved or equivalent DOT-3 brake fluid from a clean, sealed
brake fluid container, as necessary.

14. Clean the outside of the master cylinder reservoir on and around the reservoir cap prior to removing the cap and diaphragm.

Note:  Do not pressurize the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder and thereby the master cylinder
reservoir until instructed to do so by the scan tool.

15. Install the J-35589-A - Brake Bleeder Adapter and the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder to the

vehicle.

Note:  Ensure a MINIMUM of 200 kPa (30 psi) of pressure is MAINTAINED in the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A -
Brake Pressure Bleeder throughout this procedure, except as instructed.

16. Set the pressure regulator of the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder to 200 kPa (30 psi).
17. Open the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder fluid tank valve to allow pressurized brake fluid to enter

the brake system.

18. Wait approximately 30 seconds, then inspect the entire hydraulic brake system to ensure there are no existing external brake fluid leaks.
19. Secure bleeder hoses to all 4 brake caliper bleeder valves.
20. Bleed each of the 4 brake corners using the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder in the following

sequence. Ensure the brake fluid is clear and free of air bubbles at each corner.

1. Left front
2. Right front
3. Left rear
4. Right rear

21. Ensure each of the 4 brake caliper bleeder valves are tightened securely.
22. Press Start to begin the system automated bleed steps.

Follow all instructions on the scan tool. Only apply the brake pedal when instructed to do so by the scan tool.

23. When instructed, firmly apply and release the brake pedal using smooth, consistent full brake pedal strokes.

The brake pedal will go fully to the floor with some pedal feedback felt. The master cylinder reservoir supply circuit is being flushed through these
steps.

24. Continue the brake applications until instructed by the scan tool.

The scan tool will instruct to perform 10 brake applies.

25. When instructed by the scan tool, stop performing the brake applications and press Enter.

The scan tool will instruct to perform Steps 23-25 2 more times.

26. When instructed by the scan tool, press Start to continue.

Note:  The hydraulic brake system will be under high pressure during the next bleed sequence. Ensure the bleeder hose is maintained securely to
the bleeder valve, and open the bleeder valve slowly.

27. Following the instructions on the scan tool, open the left rear (LR) brake caliper bleeder valve.
28. With the bleeder valve open and the bleeder hose maintained firmly in place, press Start to begin the bleeding process.

This process will run in a 30 second cycle. The pump and HPA circuits are being flushed during these steps.

29. Press Enter when instructed to repeat the bleeding process 5 more times on the scan tool.
30. Press Enter when instructed at the end of the 6th bleeding process.
31. Ensure the LR brake caliper bleeder valve is tightened securely.
32. Reduce the charge in the air tank of the J-29532 - Diaphragm Pressure Bleeder , or J-29532-A - Brake Pressure Bleeder to 0 kPa (0 psi).
33. Press Start to continue.

The brake pedal simulator circuit is being flushed through this step.

34. Place shop cloths beneath the master cylinder brake pipe connections to protect the vehicle from the brake fluid expelled during the next sequence.
35. When instructed by the scan tool, set the pressure regulator of the J-29532 - Diaphragm Pressure Bleeder or charge the air tank of the J-29532-A -

Brake Pressure Bleeder to 200 kPa (30 psi).

Antilock Brake System Automated Bleed Procedure|Page 1515 > < Antilock Brake System Automated Bleed Procedure