saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Power Outlet Receptacle Inoperative|Page 7810 > < Power Outlet Receptacle Inoperative|Page 7808
Page 3
background image

3. Test for less than 3 ohms between the following terminals:

*

The terminal 6 and the line hot terminal

*

The terminal 3 and the line neutral terminal

‹› If greater than the specified range, replace the accessory power outlet.

4. Test for infinite resistance between terminal 4 and terminal 1.

‹› If not the specified value, replace the accessory power outlet.

5. Connect an AC powered device to the accessory power outlet. 
6. Test for less than 3 ohms between terminal 4 and terminal 1.

‹› If greater than the specified range, replace the accessory power outlet.

7. Test for 2.9-3.1 volts, with the DMM set on the diode setting and the positive test lead to terminal 6 and the negative test lead to terminal 3.

‹› If not within the specified range, replace the accessory power outlet.

8. Test for 0.0-0.1 volts, with the DMM set on the diode setting and the positive test lead to terminal 3 and the negative test lead to terminal 6.

‹› If greater than the specified range, replace the accessory power outlet.

Repair Instructions

Perform the Diagnostic Repair Verification   (See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble
Code Tests and Associated Procedures/Verification Tests and Procedures) after completing the diagnostic procedure.

*

120-Volt Accessory Power Receptacle Replacement   (See: Service and Repair/120-Volt Accessory Power Receptacle Replacement)

*

Control Module References   (See: Testing and Inspection/Programming and Relearning) for control module replacement, setup, and programming

Power Outlet Receptacle Inoperative|Page 7810 > < Power Outlet Receptacle Inoperative|Page 7808