xB L4-1.5L (1NZ-FE) (2004)
Compressor HVAC: Testing and Inspection
INSPECT W/PULLEY COMPRESSOR ASSY
a. Check the operation.
1. Start the engine.
2. Inspect the compressor pulley.
Standard: The compressor shaft rotates along with the pulley
b. Inspect w/pulley compressor assy.
1. Disconnect the connector.
2. Measure the resistance according to the value(s) in the table.