xB L4-1.5L (1NZ-FE) (2004)
NOTE:
While performing the Zero Point Calibration, do NOT tilt, move, or shake the vehicle.
The vehicle must remain in a stationary condition throughout the entire process.
Be sure to perform the procedure on a level surface with an inclination of less than 1%.
3.
Drive the vehicle for at least 5 minutes to confirm Zero Point Calibration is complete.
NOTE:
If viewing Diagnostic Tester Data List after repair, the Steering Angle Sensor may remain at 1150 until the vehicle reaches 28 mph. This is a
normal condition until the learned values of the steering angle have been achieved.
Calibration Procedure With SST
Zero Point Calibration Using SST 09843-18040
The following procedure may be used in the cases where a Diagnostic Tester is not available.
NOTE:
While performing the Zero Point Calibration, do NOT tilt, move, or shake the vehicle.
The vehicle must remain in a stationary condition throughout the entire process.
Be sure to perform the procedure on a level surface with an inclination of less than 1%.
1.
If the vehicle is equipped with A/T, ensure that the shift lever is in the "P" range and the parking brake is applied. If the vehicle is equipped with a
M/T, ensure that the parking brake is applied.
2.
Turn the ignition switch ON.