(a) Measure the resistance.

Standard resistance:

(b) Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve

connector, and check the operation of the valve.
NOTICE:  While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short
circuit may occur.

OK:
The solenoid makes an operating sound.

If the resistance is not as specified, replace the shift solenoid valve SL2.

3. INSPECT SHIFT SOLENOID VALVE SLT