(a) Measure the resistance.

Standard resistance:

(b) Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve

connector, and check the operation of the valve.
NOTICE:  While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short
circuit may occur.

OK:
The solenoid makes an operating sound.

If the resistance is not as specified, replace the shift solenoid valve SLT.

4. INSPECT SHIFT SOLENOID VALVE DSL

(a) Measure the resistance.

Standard resistance:

(b) Connect the positive (+) battery lead to the terminal of the solenoid connector, and the negative (-) battery lead to the solenoid body, and check

the operation of the valve.
NOTICE:  While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short
circuit may occur.

OK:
The solenoid makes an operating sound.

If the resistance is not as specified, replace the shift solenoid valve DSL.

5. INSPECT SHIFT SOLENOID VALVE S4

(a) Measure the resistance.

Standard resistance: