seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Erasing fault memory > < Interrogating fault memory
Automatic gearbox 099 4WD -self-diagnosis-
Performing self-diagnosis
Fault table
  • ◆ All the possible faults which are recognised by the automatic gearbox control unit -J217- and displayed on the V.A.G 1551 with the printer switched on when the fault memory is interrogated, are listed below grouped according to the fault code number.
  • ◆ If faults occur only occasionally or if the fault memory was not erased after rectifying the faults, these faults will be displayed as "sporadic faults" for a stipulated period of time =>Gearbox control unit fault recognition, Page 01-5.
  • ◆ If components are indicated as being faulty during fault memory interrogation, additionally test wiring to the components for short and open circuits according to current flow diagram =>"Current flow diagrams, Electrical fault finding and Fitting locations" binder, Alhambra 1996 ▸.
  • ◆ The fault code is printed out in the "rapid data transfer" mode only when the printer of V.A.G 1551 is switched on.
    Example: Fault code (5-position) 65535

Output on printer
V.A.G 1551

No fault recognised!

If "No fault recognised" appears after performing repairs, the self-diagnosis is completed.
In the event that the automatic gearbox does not operate properly despite self-diagnosis, carry out repairs as per fault finding programme.
=> "Fault finding, Power transmission" binder, No. 14

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00258

Wiring open or short circuit

- Check wiring and connections according to CFD2)

Solenoid valve 1 -N88-

Solenoid valve 1 -N88- defective

- Read measured value block ; display group number 004

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

00260

Wiring open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 2 -N89-

Solenoid valve 2 -N89- defective

- Read measured value block ; display group number 004

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00262

Wiring open or short circuit

- Check wiring and connections according to CFD 2)

Solenoid valve 3 -N90-

Solenoid valve 3 -N90- defective

- Read measured value block ; display group number 004

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

00264

Wiring open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 4 -N91-

Solenoid valve 4 -N91- defective

- Read measured value block ; display group number 004

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00266

Wiring open or short circuit

- Check wiring and connections according to CFD 2)

Solenoid valve 5 -N92-

Solenoid valve 5 -N92- defective

- Read measured value block ; display group number 004

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

00268

Wiring open or short circuit

- Check wiring and connections according to CFD 2)

Solenoid valve 6 -N93-

Solenoid valve 6 -N93- defective

- Read measured value block ; display group number 002

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00270

Wiring open or short circuit

- Check wiring and connections according to CFD 2)

Solenoid valve 7 -N94-

Solenoid valve 7 -N94- defective

- Read measured value block ; display group number 004

Open circuit1)
Short to earth1)
Open circuit/short to earth1)
Short to positive1)

- Perform electrical check =>from page 01-73

00281

Open circuit in wiring

- Check wiring and connections according to current flow diagram

Road speed sender -G68-

No signal

Road speed sender -G68- defective

- Read measured value block , Fig. 10

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00293

Wiring open circuit

- Check wiring and connections according to CFD 1)

Multifunction switch -F125-

Multifunction switch -F125- defective

- Read measured value block ; display group number 001

Undefined switch state

- Perform electrical tests =>from page 01-19, Fig. 8

1)    First check connectors for contact corrosion or water ingress and renew if necessary.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00297

Wiring open circuit

- Check wiring and connections according to current flow diagram

Gearbox speed sender
-G38-

No signal1)

Gearbox speed sender -G38- defective

- Perform electrical check =>from page 01-20, Fig.9

Implausible signal1)

If the control unit recognises an implausible signal, the connectors for gearbox speed sender -G38- and road speed sender -G68- are interchanged

00300

Wiring open circuit

- Check wiring and connections according to CFD 2)

Gearbox oil temperature sender -G93-1)

Gearbox oil temperature sender -G93- defective

- Read measured value block ; display group number 005

No fault type recognised

- Perform electrical check =>from page 01-73

1)    A faulty ATF temperature sender is indicated.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00518

Wiring open or short circuit

- If in addition fault 00638 is displayed, then rectify this first

- Check wiring and connections according to current flow diagram

Throttle valve potentiometer -G69-


Signal outside tolerances

Defective engine control unit or defective throttle valve potentiometer -G69- (in throttle valve control part)

The signal from throttle valve potentiometer -G69- is directed via engine control unit to gearbox control unit
and can only be checked in measured value block.
If a fault is indicated in the throttle valve potentiometer, then also carry out a self-diagnosis on engine control unit.

- Read measured value block

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00529

Open circuit in wiring

- Check wiring and connections according to CFD

Speed information missing

- Read measured value block =>page

- Perform electrical check =>from Page 01-73

00532

Battery defective

- Test battery voltage

Supply voltage

Insufficient system voltage for valves

- Read measured value block

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00545

Wiring open circuit or short earth

- Check wiring and connectors according to current flow diagram

Engine/gearbox electrical connection

Open circuit1)
Short to earth1)
Open circuit/short to earth1)

No engine/gearbox control unit connection
The signal for influencing the ignition timing point is not transferred or transferred erroneously between engine and gearbox control unit

- Read measured value block

00596

10 pin connector between valve body conductor strip and wiring loom

- Check wiring and connections according to CFD

Short circuit between valve wiring

Conductor strip to valve body defective

- Perform electrical check => from page

1)    One of these displays appears in addition to relevant component.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00638

Wiring open circuit or short to earth

- Check wiring and connections according to CFD

Engine/gearbox electrical connection 2

No signal

No engine/gearbox control unit connection
Throttle valve signal not transferred to gearbox control unit

- Read measuring value block

00641

Gearbox becomes too hot, max. 148°C. If ATF temperature is too high, gearbox shifts down into next lower gear.

- Check ATF level
=> Repair group 37; Checking ATF level and topping-up01-50; display group number 05; read off ATF temperature

ATF temperature

Trailer load of vehicle too high

- Check wiring and connections according to current flow diagram

Signal too large1)
No fault recognised1)

ATF level not in order
Gearbox oil temperature sender (ATF) defective

- Replace conductor strip

1)    One of these displays appears in addition to relevant component.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00652

Gear monitoring

Electrical/hydraulic fault

Clutch or valve body defective

- Read measuring value block ; display group number 04 and establish by driving in which gear the fault occurs

Implausible signal

00660

Open circuit in wiring

- Check wiring and connections according to CFD

Kickdown switch/throttle valve potentiometer

Throttle valve potentiometer -G69- defective

- Perform repairs as described in "Rectifying fault" 00518 -Throttle valve potentiometer -G69-

Implausible signal

Kickdown switch -F8- defective

- Read measured value block =>page

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

01192

Torque converter lock-up clutch

mechanical fault

Torque converter lock-up clutch slipping
Valve body defective

- Check torque converter lock-up clutch slip
Read measured value block ; display group number 007

01236

Selector lever lock solenoid -N110-

Open circuit/short to earth

Wiring open circuit or short to earth
Selector lever lock solenoid -N110- defective

- Read measured value block ; display group number 005

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

65535

- Renew control unit

Control unit defective

Control unit -J217- defective

- Bring system into basic setting

The control unit -J217- should not be renewed until the possible cause of the fault has been determined and the following faults have been rectified:

  • ◆ mechanical faults
  • ◆ hydraulic faults
  • ◆ all affected electrical/electronic components and cable connections.

Erasing fault memory > < Interrogating fault memory