| Release the sealing lip from the glass flange using the plastic wedge and apply or spray sliding agent (cleaning solution). |
–
| Using the small tube -2- fit the cutting wire on the glass flange. |
–
| If the opening is too tight, lead the cutting wire out and press it, using the plastic wedge, under the lip. |
|
|
|