Functional check of sender
-
‒ Observe coolant temperature figure in display zone 2. The temperature figure must
increase uniformly and without interruption.
- If a temperature figure is displayed which deviates greatly from the senders ambient temperature, check sender wiring for transfer resistances.
Notes:
-
◆ Depending upon the temperature level, the display on fault reader will jump by 2...5 °C
-
◆ If irregular engine running occurs in certain temperature ranges and the temperature figure does not increase without interruption, the temperature signal is temporarily interrupted and the sender must be renewed.
-
‒ Press the ⇒key.
-
‒ Press keys 0 and 6 for the "End data transfer" function and confirm input with the Q key.
If the figure does not increase uniformly:
-
‒ Renew coolant temperature sender (G62).
If a G62 fault is indicated in fault memory even though the figure increases uniformly:
|