‒ Observe Lambda probe voltage in display zone 3. The voltage must fluctuate
at least 10 times per minute in the range 0...1.1 V.
If the probe factor does not fluctuate as stated:
-
‒ Carry out road test and burn Lambda probe clean and repeat check.
If the specifications are not obtained again:
-
‒ Check Lambda probe heating => Page 24-33.
If the displayed figure remains constant:
-
‒ Press the ⇒key.
-
‒ Press keys 0 and 6 for the "End data transfer" function and confirm input with the Q key.
-
‒ Switch off ignition.
-
‒ Continue check according to following table.
|
---|
Display
|
Cause
|
Continuation of check
|
approx. 1.60 V
|
Open circuit
|
=> Page 24-31, checking Lambda probe wiring
|
approx. 2.51 V
|
Short to positive
|
|
approx. 0.19 V
|
Short to earth
|
|
fluctuates between 0...1.1 V
|
Control OK.
|
---
|
If the specifications for Lambda control operating conditions are not attained or the probe voltage does not fluctuate as stated:
Checking Lambda probe wiring
|