| Fit the support -A-, taking into account that the support guide -D- is fitted correctly into the allotment in the air inlet opening -E- and that the support correctly inserts into both slots -B- and -C-. |
–
| Test the servo motor, the support -A- must hold it in position; if there is some play then eliminate it by applying some spongy material to the interior of the attachment points -F- of the support -A- |
Note! t
| The position of the servo motor (and the flap) is not visible when the glove compartment is fitted, for this reason, the operation of the servo motor must be tested before fitting the glove compartment → Chapter. |
t
| If both cogwheels are not fitted in the correct position, the fresh air / air recirculation flap will not reach the two final positions or the servo motor will function in an irregular manner and may jam. |
–
| Check the operation of the Servomotor for the fresh air / air recirculation flap -V154- and the activation by the Heating control unit -J65- → Chapter. |
|
|
|