Adaptation of refrigerant loading machines before SAT 4006D to rinse circuits with the Kit SAT 4009 |
R134a refrigerant loading machines supplied by SEAT after the model SAT 4006D, have the Kit SAT 4006D already included. |
Machines prior to the model SAT 4006D supplied by SEAT require installation of the for rinsing of R134a refrigerant circuits. |
Note t
| Additional information ⇒ Operating instructions of the device itself |
t
| Additional information ⇒ Assembly instructions of the manufacturer rinsing set |
t
| Catalogue of tools and utilities. |
WARNING Before installation, the air-conditioning station should be disconnected from the electricity supply. |
|
–
| Ensure that the content of the cleaning kit is complete. |
Special tools and workshop equipment required |
t
| Case with support or adapter SAT 4009D → Chapter |
t
| Connection kit with ball valve. |
t
| Filter with attachment bracket. |
|
|
|