Service stations connection to carry out measurements and inspections |
–
| Connect the service station to the electrical power source. |
–
| Attach the quick coupling adaptors to the charging hoses of the service station (wheels or manual shut-off valves not open). |
–
| Connect the service station and vacuum the charging hoses (only necessary if there is air inside the charging hoses). |
–
| Disconnect the service station. |
–
| Unscrew the caps from the service connections (with valve). |
–
| Connect the service station to the service connections of the refrigerant circuit on the vehicle with the quick coupling adaptors. |
–
| Turn the wheel on the quick coupling adaptors until the refrigerant circuit connection valves are completely open (check the manometer; do not over-pressurize the valves). |
–
| Carry out the planned inspections and measurements. |
|
|
|