Quantity of refrigerant R134a, quantity of the refrigerant oil: SEAT vehicles > < After cleaning the refrigerant circuit, e.g. due to moistness (the refrigerant circuit was left open over a longer period) or di
If the refrigerant does not have to be cleaned (e.g damaged in an accident), no refrigerant has escaped and no ingress of moisture and dirt into refrigerant circuit
If the refrigerant does not have to be cleaned (e.g damaged in an accident), no refrigerant has escaped and no ingress of moisture and dirt into refrigerant circuit
–  Drain refrigerant circuit.
–  Replace the choke.
–  Disassemble the fluid tank or collecting tank.
–  Clean any dirt in the liquid tank or collecting tank.
–  Weigh the disassembled liquid tank or collecting tank.
  Note
t  Fill the new liquid tank or collecting tank with as much refrigerant oil as necessary to reach the weight of the disassembled tank.
t  Assemble the new fluid tank or collecting tank.
–  Assemble, vacuum and charge the refrigerant circuit.
   

Quantity of refrigerant R134a, quantity of the refrigerant oil: SEAT vehicles > < After cleaning the refrigerant circuit, e.g. due to moistness (the refrigerant circuit was left open over a longer period) or di