seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Fill the container of the air conditioning service station with refrigerant > < Charging the refrigerant circuit with the service station
Turn on the air conditioner after filling.
Turn on the air conditioner after filling.
  Note
If the air conditioner compressor is removed, the poly V-belt / free pulley must be turned about 10 turns by hand before starting for the first time. This prevents damage being caused when the air conditioner is commissioned for the first time by a sudden increase of the fluid quantity in the air conditioner compressor When oil is located in the cylinder of the air conditioner compressor, this will be pressed out by the rotation.
   
–  Start the engine with the compressor disconnected (version with electromagnetic coupling).
–  Set the compressor to its lowest power setting, "Econ" mode or A/C disconnected (version with regulating valve without electromagnetic coupling).
–  Wait for the engine to start idling at a stable speed.
–  Switch on compressor and allow system to run at idle for at least 2 minutes.
–  If necessary, check required pressures in refrigerant circuit with service station for air conditioners.
–  Switch off the engine.
–  Turn the wheel on the quick coupling adaptor (close).
–  Remove the hose of the refrigerant.
–  Replace the protective caps.
  N87-0528