Fitting
–  In area of hole -E- check gap between noise insulation mat and floor panel (noise insulation mat must not make contact with installed condensate drain valve -C-).
–  Check condensate drain valve -C-; it must not be gummed up with wax or underseal.
–  Check for contamination of condensate drain hose -B- and clean hose before fitting.
   
–  Fully insert condensate drain valve -C- as shown (use soap solution as lubricant if applicable).
–  Check condensate drain hose -B-. It must not be twisted or crushed and must be positioned in recess provided in floor covering.
–  Fasten the clip -A-.
–  Re-install all components removed in reverse order.