t
| In the casing -C- the Fresh air blower -V2- and the Fresh air blower control unit -J126- are fitted and cannot be replaced separately → Parts catalogue. |
WARNING The heat sink at the fresh air blower control unit -J126- may be hot. |
|
–
| Remove housing of fresh air blower-C- from air conditioning unit. |
Caution Do not touch the wheel of the fresh air blower -V2-; the use of force on the wheel or movement of the counterweights can cause imbalance which could lead to malfunction. |
|
Re-install all parts removed in reverse order; note the following: |
Note t
| When installing, make sure that fresh air blower is correctly seated in air conditioning unit. |
t
| Following the installation, check the correct positioning of the fresh air blower casing in the air conditioning and the operation of the Fresh air blower control unit -J126-. |
|
|
|