Removing and installing air recirculation flap control motor -V113- |
Note t
| An end switch is mounted in the recirculated-air flap servomotor -V113-. |
t
| The air flow flap (fresh air flap) ia actuated using a cam disk and a lever of the Recirculated-air flap servomotor -V113-. |
t
| Check the function of the servomotor as follows, for example: connect both contacts „5“ and „6“ to a plug of the control motor to a 12 V direct current voltage source. Control motor then moves only in one direction as far as stop. Interchanging positive and negative reverses direction. Use an adapter lead for this purpose → Chapter. |
t
| With the function „basic adjustment“ additional tests can be done for the activation of the air conditioning electric components, for example, that they are not mixed up → Vehicle diagnostic tester. |
|
|
|