Install in reverse order. |
Note t
| When you replace a control and indication unit, take note of the exact assignation: → Parts catalogue |
t
| If you fit a new -E87- and do not do the basic configuration, the regulating valve for the compressor -N280- will not be activated and in the measured values block “2” of the self diagnostic for the air conditioning will show it as deactivated “6”. |
t
| Functions selected are indicated by lighting of light-emitting diodes (LEDs) in the various -E87- buttons. |
t
| In this version of the -E87- the thermosensor - dashboard -G56- are integrated. The air turbine for the thermosensor -V42- is fitted and cannot be replaced. |
t
| After replacing the -E87-, fundamentally: |
–
| Perform the basic configuration. |
–
| Consult the fault memory. |
t
| By pressing the button “Temperature +”, while keeping the “air recirculation button” pressed (for more than 2 seconds), you can change the indication of the -E87-, from °C to °F and viceversa. |
|
|
|