Detaching and attaching compressor from support > < The pressure signal of the High pressure sender G65 .
O-rings for refrigerant circuit
O-rings for refrigerant circuit
t  The O-rings may only be used once, replace them every time they are removed.
t  Lightly oil the O-rings with oil from the refrigerant circuit just before fitting.
t  Ensure that the O-rings sit correctly into the corresponding tubes or grooves.
t  Work in a clean area (even small impurities such as a hair for example can cause leaks).
  Note
t  Only fit O-rings that are resistant to the refrigeration agent R134a and to the corresponding oil. These O-rings are easily identified by their colour to avoid possible confusion (currently “red”, “purple” or “violet”) → Spare parts catalogue.
   
t  The measurements -a- and -b- are different, depending on the fitting position of the O-rings → Spare parts catalogue.
t  In addition to the colour-coded O-ring seals, use is also made of black O-ring seals for certain connections.
  A87-0021