Instructions for filling the compressor |
After first filling the refrigerating circuit or after cleaning the refrigerating circuit, all the refrigerant oil is in the compressor. |
To avoid damaging the compressor on starting, proceed as follows: |
–
| Locate the dial control for air distribution in “central nozzle” position. |
–
| Open all the nozzles on the dashboard. |
–
| Set the fresh air fan switch at least to level 3. |
–
| Turn the temperature selection control to the left as far as it will go (minimum temperature). |
–
| After the idling has settled (approx. 5 sec.) switch on the air conditioning. |
–
| Leave the engine idling continuously for at least 5 minutes. Maximum engine revolutions: 2500 rpm. |
–
| Then switch off the air conditioning. |
In this way the oil will be distributed in the refrigerant circuit and the compressor can then be used at full power. |
|
|
|