Procedure > < Quick connectors for the refrigerant pipes
Disconnecting the quick connectors for the refrigerant pipes
Disconnecting the quick connectors for the refrigerant pipes
Special tools and workshop equipment required
   
t  Unblocking tool -VAS 6127/3- (for low pressure piping)
t  Pliers for lock washers
t  Protective goggles
t  Gloves
  Note
t  Evedry time you remove a quick connector, replace the O-rings, the locking element and the lock washer.
t  These parts are available as a repair set.
t  The following describes how to remove the quick connector from the low pressure pipe. The procedure for removing the quick connector from the high pressure pipe is identical.