SEAT Workshop Service and Repair Manuals
HOME
FEATURES
MENU
INDEX
ABOUT US
Control unit for the temperature flap: removing and fitting >
< Removing
Leon Mk2
Heating, ventilation, air conditioning system
Heating and air conditioning / Heating
Supplementary heating element Z35 : checking / r_distribution_flap_control_mechanism_removing_and_fitting/">Air distribution flap control mechanism removing and fitting
Fitting
Fitting
Fitting
–
Lock the notched wheels of the control unit.
To do so, the notched wheels should turn so that the marks
-arrows-
match.
–
In this position, insert an M6 bolt
-2-
in the opening of the lower notched wheel and the casing.
–
Lower the lever of the flap for the floor compartment nozzle
-1-
-arrow-
(flap closed).
–
Lower the lever of the flap for the instrument panel nozzle
-2-
arrow (flap closed).
–
Place the lever of the demister flap
-3-
so that the demister flap is completely open.
–
Insert the locked control unit
-5-
at an angle into the 3 openings in the casing.
–
Place the control unit close to the casing so that lever rods
-1-
and
-2-
fit with the corresponding giudes in the control unit
-5-
.
–
Insert the support rods
-3-
in the corresponding openings of the control unit
-5-
.
Note
The lever rod is also visible in the assembly
-1-
from the outside through a view hole in the lower notched wheel of the control unit.
–
Fit the control unit
-5-
into place.
–
Unscrew bolt
-4-
.
–
Check the working of the control unit
-5-
.
All the flaps should move easily and without tugging until reaching their final position.
The control unit does not have a maximum position. It should be possible to turn it several times in the same direction.
The flap control does not operate correctly:
–
Dismount the control unit and repeat the assembly process as described above.
The flap control operates correctly:
–
Bolt down the control unit (Nm).
Heating, ventilation, air conditioning system
Heating and air conditioning / Heating
Supplementary heating element Z35 : checking / r_distribution_flap_control_mechanism_removing_and_fitting/">Air distribution flap control mechanism removing and fitting
Fitting
Control unit for the temperature flap: removing and fitting >
< Removing