| Carefully push the tranversal panel seal -1- (assembly plate) from the outside onto the groove of the connection -2- of the heat exchanger -arrow-. |
–
| Replace the o-rings of the heat exchanger connection element. |
–
| Connect the coolant hoses making sure they are in the correct position. |
In the direction of motion, right: supply |
Note When the heat exchanger is replaced, the coolant should be completely drained and replaced with new fluid. |
–
| Check the level of coolant and top up if necessary. |
|
|
|