| Remove fuel line from pressure connection of metering pump and fit a new fuel hose (length approx. 20 cm) from pressure connection to measuring glass (capacity approx. 25 ml). |
–
| Switch auxiliary heater on (with the help of a second mechanic, if required). The metering pump will start to deliver after 40 seconds. |
–
| Hold measuring glass at same height as heater unit. |
–
| After approx. 40 seconds, the fuel line is filled and bled. |
–
| Switch auxiliary heater off and empty measuring glass. |
–
| Switch auxiliary heater on again. |
–
| Hold measuring glass at same height as heater unit. |
–
| The auxiliary heater switches off automatically after 90 seconds. |
–
| Read measuring glass. Quantity delivered: petrol = 9.3 ml to 10.7 ml; diesel = 6.7 ml to 9 ml |
–
| If quantity delivered is not within specifications, renew metering pump -V54-. |
|
|
|