Fuel take-off > < Test prerequisites:
Checking:
Checking:
  WARNING
Danger of fuel escaping.
Fuel system is under pressure.
Before opening system, wrap a cloth around the connection. Then release pressure by carefully loosening the connection.
   
–  Remove fuel line from pressure connection of metering pump and fit a new fuel hose (length approx. 20 cm) from pressure connection to measuring glass (capacity approx. 25 ml).
–  Switch auxiliary heater on (with the help of a second mechanic, if required). The metering pump will start to deliver after 40 seconds.
–  Hold measuring glass at same height as heater unit.
–  After approx. 40 seconds, the fuel line is filled and bled.
–  Switch auxiliary heater off and empty measuring glass.
–  Switch auxiliary heater on again.
–  Hold measuring glass at same height as heater unit.
–  The auxiliary heater switches off automatically after 90 seconds.
–  Read measuring glass. Quantity delivered: petrol = 9.3 ml to 10.7 ml; diesel = 6.7 ml to 9 ml
–  If quantity delivered is not within specifications, renew metering pump -V54-.
  N82-0074

Fuel take-off > < Test prerequisites: