Leon Mk2
Dismantling and assembling auxiliary heater -D3W- |
1 - | Water jacket cover |
2 - | Bolt M5×12 |
3 - | Heat exchanger |
q | Clean inside and outside with brass wire brush (spark plug brush). |
q | Note installation position → Fig.. |
4 - | O-ring |
q | Renew |
q | Lubricate when installing. |
5 - | Seal |
q | Always renew after dismantling. |
6 - | Combustion chamber with flame tube |
q | Clean inside and outside with brass wire brush (spark plug brush). |
7 - | Combustion air blower cover |
8 - | Bolt M5×22 |
9 - | Bolt M4×10 |
10 - | Socket head screw M5×65 |
q | 6 Nm |
11 - | Socket head screw M5×16 |
q | 6 Nm |
12 - | Heater control unit -J162- |
q | Removing → Chapter |
q | Checking → Chapter |
13 - | Combustion air blower -V6- |
q | Do not dismantle further |
q | Checking → Chapter |
14 - | Cover |
15 - | Rubber grommet |
16 - | Seal |
q | Always renew after dismantling. |
17 - | Flame monitor -G64- |
q | Removing → Chapter |
q | Checking → Chapter |
18 - | Glow plug for heater -Q9- |
q | Removing → Chapter |
q | Clean glow plug with brass wire brush (spark plug brush). |
q | 6 Nm |
q | Checking → Chapter |
19 - | Water jacket |
q | Clean inside and outside with brass wire brush (spark plug brush). |
20 - | Overheating sensor -G189- |
q | Checking → Chapter |
21 - | Temperature sensor -G18- |
q | Checking → Chapter |
22 - | Spring |
q | Do not bend further. |
q | Renew if damaged. |
23 - | Screw M5×16 |
|