Safety precautions for vehicles with start/stop system > < Note on supplementary heater operation in vehicles with diesel engine
Notes for vehicles with a start-stop system
Notes for vehicles with a start-stop system
If a start-stop system is installed, the following abort conditions will deactivate the start-stop function:
t  The start-stop system has been switched off via the start-stop mode button.
t  The charge condition of the battery is insufficient to restart the engine (starting voltage prediction).
t  The defrost function is active.
t  The windscreen heater function is active.
t  The air conditioner system temperature set in the control element deviates by more than 8 °C from the actual temperature of the interior.
t  The engine speed is greater than 1200 rpm.
t  The alternator -C- is defective, i.e. belt broken.
t  Coolant temperature not within specifications of 25 °C - 100 °C.
t  Blower speed increase by more than 4 stages.
Additional information:
t  Further information about this can be found in the self-study program.
   