| Press catches -2- in -direction of arrow A- to the side, using a suitable tool. |
–
| Press metering pump -V54- together with bracket upwards in -direction of arrow B- and swivel upwards. |
–
| Separate connector -1- from metering pump -V54-. |
WARNING Fuel system is under pressure. |
Before opening the system place a cloth around the connection. Then release pressure by carefully loosening the connection. |
|
–
| Pull fuel line -3- off metering pump -V54- and seal. |
–
| Open quick-release coupling -6- of fuel line leading to Thermo Top V auxiliary heater and seal fuel line. |
|
|
|