SEAT Workshop Service and Repair Manuals
HOME
FEATURES
MENU
INDEX
ABOUT US
Ignition transformer and output stage: checking >
< Ignition timing: checking and adjusting
Leon Mk2
Power unit
1AV Injection and Ignition System
Ignition system, glow plug system / Ignition system: Repairing
Hall sender: checking
Hall sender: checking
Hall sender: checking
Special tools and workshop equipment required
t
Hand multimeter -V.A.G 1526 A- or multimeter -V.A.G 1715-
t
Auxiliary measuring set -V.A.G 1594 C-
t
Test box -V.A.G 1598/18-
t
Current flow diagram
Test conditions
l
Hall sender fault detected by self-diagnosis.
Checking process
–
Remove the connector of the Hall sender (ignition distributor).
–
Connect multimeter to the connector external contacts to measure voltage using auxiliary cables from -V.A.G 1594 C-.
–
Switch ignition on.
Specification: 9 V min
–
Switch ignition off.
–
Connect test box -V.A.G 1598/18- to control unit wiring harness.
–
Check wiring for open circuit between test box and connector using current flow diagram.
Contact
Test box -V.A.G 1598/18-, socket
1
17
2
13
3
8
Wire resistance: 1,5 Ω max.
–
Also check wires for short circuits to one another.
Specification: ∞ Ω
If no wiring fault is detected and voltage was present between contacts 1+3:
–
Replace Hall sender -G40-
→ Item
.
If no wiring fault is detected and no voltage was present between contacts 1+3:
–
Renew engine control unit
→ Chapter
Power unit
1AV Injection and Ignition System
Ignition system, glow plug system / Ignition system: Repairing
Hall sender: checking
Ignition transformer and output stage: checking >
< Ignition timing: checking and adjusting