Continue for both models of pump-injector unit |
–
| If necessary, re-adjust the pump-injector and tighten the fixing screw as follows: 12 Nm and 270° (3/4 turn) (the tightening process can be carried out in various stages) |
–
| Fit the rocker arm shaft and tighten the fixing screws as follows. |
–
| Uniformally tighten the internal, then the external screws, by hand. Next, and in the same order, tighten to 20 Nm and ¼ turn (90°). |
|
|
|