Air filter > < Lambda probe and exhaust gas temperature sensors: Assembly overview
Removing and installing Lambda probeG39 with Lambda probe heaterZ19
Removing and installing Lambda probe -G39- with Lambda probe heater -Z19-
Special tools and workshop equipment required
   
t  Lambda probe open ring spanner set -3337-
Removal:
–  Remove engine cover panel → Chapter.
  W00-0206
–  Unplug electrical connector -1- on the Lambda probe -G39-.
–  Unscrew Lambda probe -G39--2- using tool from Lambda probe open ring spanner set -3337-.
Installation
Installation is carried out in reverse sequence; note the following:
  Note
t  New Lambda probes are coated with an assembly paste. The paste must not get into the slots on the probe body.
t  In the case of a used Lambda probe grease only the thread with high-temperature paste. The paste must not get into the slots on the probe body. For high-temperature paste refer to → Electronic parts catalogue
t  When installing, the Lambda probe wiring must always be reattached at the same locations to prevent it from coming into contact with the exhaust pipe.
l  Tightening torque → Chapter
  A23-10581

Air filter > < Lambda probe and exhaust gas temperature sensors: Assembly overview