| Connect hand vacuum pump -SAT 1390- to valve. |
| The membrane should move in the direction of the vacuum connector (check by touching from underneath -arrow-). |
–
| Extract the manual vacuum pump hose from the exhaust recirculation valve. |
| The closing of the valve should be audible (the membrana moves toward the intake manifold). |
–
| On the intake duct, loosen the clamp on the connecting pipe between the intercooler and the intake duct. |
–
| Extract the vacuum hose from the exhaust recirculation valve. |
–
| Connect the manual vacuum pump valve -SAT 1390-. |
|
|
|