Press keys 0 and 8 for the function “Read measured value block” and confirm entry with Q key.
Rapid data transfer HELP
Select function XX
Indicated on display:
–
Press keys 0, 0 and 2 for “Display group number 2” and confirm entry with Q key.
Read measured value block HELP
Input display group number XXX
–
–
Check accelerator pedal position display in display zone 2. The accelerator pedal must not be depressed. Specification: 0.0 %
Read measured value block 2 →
0 rpm 0.0 % 0 1 0 18.4 °C
–
–
Depress accelerator pedal slowly until fully down and observe display zone 2. The value for the accelerator pedal position must increase continuously and shortly before full throttle stop reach 100 %.
Read measured value block 2 →
0 rpm 100.0 % 0 0 0 18.4 °C
–
If necessary adjust accelerator pedal -2- by turning the adjustment screw -1- so that when accelerator pedal is not depressed (idling position) 0.0 % and with accelerator pedal depressed to just before full throttle position 100 % is displayed.