Checking combi-valve
Checking combi-valve
Checking combi-valve
Special tools and workshop equipment required
t
Hand vacuum pump -SAT 1390-
Check conditions
l
Vacuum pipes and hose connections free of leaks.
l
Vacuum pipes not blocked/kinked.
Test sequence
–
Pull vacuum hose
-1-
off secondary air inlet valve
-2-
-N112-.
–
Connect hand vacuum pump -SAT 1390- to vacuum hose
-1-
.
Note!
Do not use compressed air during the following check!
–
Detach pressure hose
-3-
from secondary air pump motor and blow lightly into hose
-arrow-
. Combi-valve must be closed.
–
Operate hand vacuum pump. Combi-valve must open.
If the combi-valve does not open:
–
Replace the combi-valve