| Connect adapters -VAG 1318/11- and adapter -VAG 1318/23- to pressure tester and place adapter end in a measuring container. |
–
| Close pressure gauge cut-off tap (lever at right-angles -B-). |
–
| Operate remote control at short intervals until a pressure of 3 bar has built up. |
DANGER! Danger of spray when opening the shut-off tap, hold container over the pressure gauge free connection. |
|
–
| If pressure builds up too high, lower excess pressure by carefully opening the shut-off tap. |
–
| Observe pressure drop on tester. After 10 minutes the pressure must not drop below 2.5 bar. |
If the pressure drops further: |
–
| Check that there are no leaks in the pipe connections. |
If no leaks are observed in the pipes: |
–
| Check fuel delivery unit . |
|
|
|