Checking exhaust gas recirculation cooler change-over
Checking exhaust gas recirculation cooler change-over
Special tools and workshop equipment required
   
t  Vacuum pump -VAS 6213-, see equivalent → Anchor
  W00-10259
Operation process
–  Detach heat shield sleeve.
–  Remove the vacuum hose from the vacuum socket and connect the Manual vacuum pump -VAS 6213- instead.
–  Operate hand vacuum pump to create a vacuum.
l  The linkage of the exhaust gas recirculation cooler changeover must move -arrows-.
If linkage does not move or only moves in jerks:
t  The vacuum unit is defective.
t  The change-over flap for exhaust gas recirculation is sticking.
  Note
When fitting the heat protection plate, fit to the same location.
  A26-10878