seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Adjusting non-contact gap of unit injectors > < Unit injector with new solenoid valve nut
Continuation for all unit injectors
Continuation for all unit injectors
–  If necessary, adjust the unit injector and tighten the securing bolt as follows:
–  Tighten securing bolt to 12 Nm and turn 270° (3/4 turn) further (turning further can be done in several stages).
   
–  Fit rocker arm shaft and tighten new securing bolts as follows:
–  First tighten inner bolts -2- then outer bolts -1- by hand. Then using same sequence, tighten to 20 Nm and turn 90° (1/4 turn) further. Now turn the adjuster screw into rocker arm until significant resistance can be felt (unit injector is at limit stop).
  A15-0531

Adjusting non-contact gap of unit injectors > < Unit injector with new solenoid valve nut