Leon Mk2
|
1 - | Supply line |
q | Check for secure seating. |
q | To tandem pump → Item. |
q | White or with white marking. |
2 - | Return line |
q | Check for secure seating. |
q | From heat exchanger for fuel cooler, connection: radiator outlet → Item |
q | Blue or with blue marking |
3 - | O-ring |
q | Renew. |
4 - | Regulating valve |
q | Installation position: arrow points towards fuel tank |
q | When changing filter, remove retaining clip and take off regulating valve with fuel lines still attached. |
q | Below + 15 °C: passageway to filter open |
q | Over + 31 °C: passageway to filter closed |
5 - | Securing clip |
q | Check for secure seating. |
6 - | Return line |
q | To fuel tank |
q | Clipped onto bulkhead |
q | Blue or with blue marking |
q | Check for secure seating. |
7 - | Supply line |
q | From fuel tank |
q | Clipped onto bulkhead |
q | White or with white marking. |
q | Check for secure seating. |
8 - | Fuel filter |
q | Fill with diesel before installing |
q | Flow direction is marked by arrows |
q | Do not interchange connections. |
q | Renew if damaged |
9 - | Gasket |
q | Renew if damaged |
10 - | Water drain screw |
q | To bleed remove regulating valve securing clip and remove regulating valve complete with connected fuel lines. |
q | Loosen and allow approx. 100 cm3 fluid to drain |