| Connect voltage tester wire to battery positive (+) using clamps from auxiliary measuring set. |
–
| Place test probe of voltage tester on each glow plug one after the other. If diode lights up, glow plug is OK. If diode does not light up, replace glow plug. |
–
| Remove and install glow plugs with U/J extension and socket, 10 mm -3220-. Specified torque: 15 Nm. |
|
|
|