| Then connect the manual vacuum pump -VAS 6213- using the adaptor set -V.A.G 1318/17- to the piping which goes to the activated carbon filter. |
–
| Operate the manual vacuum pump -VAS 6213- a few times. Vacuum must not build up. |
–
| Check if the ventilation hose → Item of the activated carbon filter is dirty, and clean if necessary. |
If a vacuum does not build up: |
–
| Temporarily block breather hose → Item and operate vacuum pump several times. A vacuum must build up. |
If a vacuum does not build up: |
–
| Renew active carbon filter. |
|
|
|