| Cut the tube nozzle off at the front mark (nozzle diameter: approx. 3 mm). |
–
| Apply the silicone-based sealant to the clean contact surface of the oil sump, as shown in the figure. The bead must: |
t
| pass by the inner edge of the boltholes -arrows-. |
Note! The sealant bead must not be thicker; otherwise excess sealant may get into the oil sump and obstruct the oil intake line filter. |
–
| Fit the oil sump immediately and tighten all the fixing bolts slightly. |
–
| Tighten all the oil sump bolts to 15 Nm. |
Note! After fitting the oil sump, let the sealant dry for about approx. 30 minutes. After that time, the oil may be added. |
Continue fitting in the reverse order of removal. |
|
|
|